Start with the question

For a first guitar-amp recording, use one supported microphone and compare its target across one speaker before changing angle or distance. Center placement often captures more bite and an edge position a mellower balance, but the useful result depends on the speaker, microphone, room and part. Record the position you actually prefer instead of treating a fixed distance as a universal setting.

What matters most

  • Record target, angle and grille distance separately.
  • Change one practical variable and return to the reference.
  • Choose the recorded result in context; no one distance suits every rig.

Name the target, angle and distance separately

Shure describes changes in loudspeaker pickup with microphone angle and distance, and contrasts a center-facing position with a more mellow off-center or edge placement. Its examples are starting positions rather than a single preferred guitar tone. The same manual also separates close pickup from the greater room contribution of a more distant position.

For a useful first record, choose one speaker and write three independent descriptions: the position of the capsule projected straight onto the grille, which way its pickup axis faces, and how far the chosen microphone reference point sits from the grille. “Off-axis” alone leaves the target and distance unknown. Here “target” names that projected capsule position, not the point where an angled axis would intersect the speaker. Keep the axis description separate.

If the microphone is side-address, follow its marked pickup side. The end of a side-address microphone is not automatically its front. Check the exact model’s instructions before using the drawing as a positioning idea.

Sources: Shure: Microphone Techniques for Recording, amplified instruments, printed pp. 15–16

Prepare one part and one recording path

Use a short part containing single notes, a chord and a deliberate ending. Keep the guitar, pickup, controls, pedals and amplifier settings unchanged for the first pass. Leave EQ and widening effects out of the comparison unless they are part of the condition you intend to test.

Set up the microphone and recording input as their manuals require. Keep the stand stable and clear of hot surfaces. Turn the amp down before repositioning close to the speaker, then return to the recorded setting for the next take. A listening comparison does not require raising the sound until it becomes uncomfortable.

Record the same passage again, or use an already supported reamping path to repeat a saved performance. Replaying by hand adds performance variation; a dry-track reamp holds the take fixed but still needs a correctly configured send and return. Note which method you used.

Open the full-size explanatory diagram.

Move across one speaker before rotating the microphone

VariableChangeKeep recorded
TargetCenter, an intermediate point, then nearer the edgeSpeaker identity, distance and microphone angle
AngleRotate the microphone at the chosen projected capsule positionCapsule position as closely as practical
DistanceMove perpendicular to the grille at the chosen projected positionTarget and axis direction

Start with a position you can reproduce, then compare two other projected capsule positions across the same speaker. There is no need to choose exact millimetre steps. Record the reference point you can identify reliably; a grille hides the cone on some cabinets, so describe an estimate as an estimate.

Return to the first position and repeat the passage. If you cannot recognise the initial comparison, check the guitar take, input gain, stand movement and listening level before assigning the difference to the target. Choose a promising target before testing the next variable. This routine is a proposal, not a report of a completed listening session.

A three-variable position map and a return-to-reference routine separate speaker target, microphone angle and distance.
Original explanatory diagram. Conditions and examples are stated in the text; not a hardware test or a scale drawing.

Test angle and distance as two further passes

After choosing a target, compare a straight-facing and an angled position. Keep the capsule location and grille gap as consistent as the hardware allows. If rotating the stand also moves the capsule, write down both changes; do not call it an angle-only result.

Then compare the chosen close position with a farther one that the room and stand allow, retaining the projected capsule position and axis direction as closely as practical. Leave the amplifier at the same setting, check input meters and preserve headroom. If you must change preamp gain, record that as a changed condition. Compare playback at similar listening loudness afterward, rather than increasing amp gain to make the quiet recording look larger.

A more distant result may include a different room balance. Decide in the actual mix whether that helps the part. If the raw recording clips, use the recording-level checks before trying to solve the sound by moving the microphone.

Save enough detail to return to the position

RecordUseful description
SourceCabinet, selected speaker, amp settings and passage
MicrophoneModel, pickup side, pattern if selectable
GeometryTarget, angle and measured or estimated grille gap
RecordingInput, gain setting and any pad or processing
DecisionPreferred condition in this mix, with remaining uncertainty

A photograph of the stand and a written reference can help you find a position again, but a photograph alone does not establish capsule distance. Keep the location of the cabinet in the room with the note. Save the audio under the corresponding condition if you record it.

When one microphone already supplies the sound you need, stop there. Adding another microphone introduces a separate signal-combination question; use phase versus polarity before assuming a second track will improve the result. A software cabinet IR is another route with its own captured position, rather than a movable physical microphone in this room.

Download the blank English record (CSV). The sheet contains no completed observations or site test results.

How this guide was prepared

Shure’s amplified-instrument discussion and position key were checked for directionality and room-pickup context. The projected-capsule position convention and repeatability routine are editorial proposals. No microphone, speaker, amplifier or audio recording was tested; distances should be recorded using a named reference point and the equipment’s own instructions.

Documentation checked .

Sources and further reading